(Publisher of Peer Reviewed Open Access Journals)

International Journal of Advanced Technology and Engineering Exploration (IJATEE)

ISSN (Print):2394-5443    ISSN (Online):2394-7454
Volume-8 Issue-76 March-2021
Full-Text PDF
Paper Title : Effect of bottom flange cleat on integrated precast slab and column panel using cold-formed steel
Author Name : Sutanto Muliawan, Anis Saggaff, Mahmood Bin Md Tahir, Saloma , Muhammad Firdaus and KM Aminuddin
Abstract :

The use of cold-formed steel currently develops very fast. It is due to its advantages such as durability, stability, non-combustibility, sustainability, and cost-effectively. On the other hand, its disadvantages are difficult to connect, low fire resistance, residual stress on the cross-section that affects buckling resistance. In the previous research, to overcome the lack of buckling resistance in cold-formed steel, the composite connection is proposed. A recent study about cold-formed steel connection is divided into non-composite and composite research. The result of composite research has a higher moment capacity than non-composite. Most of the composite research is focused on beam and column with the concrete slab above the beam. In the current study, a T-shaped of gusset plates is used as a joint connector. This study aims to investigate the effect of the bottom flange cleat on the joint capacity. The slab panel's material is a Lipped Channel Section with the size of 12524 as the frames and reinforcements. The grade of cold-formed steel is fy = 530 MPa and fu = 590 MPa, while the T-shaped plate connector's strength is S355. The bolt used has a diameter of 10 mm, fy = 800 MPa. The flange cleats used is L100×100×10×80. The parametric study was conducted based on Eurocode 3. The connection with the additional bottom flange cleat has a higher moment resistance than without the flange cleat. The additional bottom cleat's influence is that the moment resistance increased the moment resistance from 17.11 kNm to 23.32 kNm. The predicted failure mode of the connection could be the failure that occurred at the top side of the cold-formed section of the slab due to the bending.

Keywords : Cold-formed steel connection, Bottom flange cleat, Integrated precast slab, Joint flexural resistance, T-shaped plate connector.
Cite this article : Muliawan S, Saggaff A, Tahir MB, Saloma , Firdaus M, Aminuddin K. Effect of bottom flange cleat on integrated precast slab and column panel using cold-formed steel . International Journal of Advanced Technology and Engineering Exploration. 2021; 8(76):462-472. DOI:10.19101/IJATEE.2021.874022.
References :
[1]Yu WW, Laboube RA, Chen H. Cold-formed steel design. Hoboken: Wiley; 2010.
[Crossref] [Google Scholar]
[2]Saggaff A, Firdaus M, Tahir MM, Ngian SP, Siang TC, Aminuddin KM, Salih MN. Experimental study on composite connection with double lipped c-sections. In IOP conference series: materials science and engineering 2020 (pp. 1-9). IOP Publishing.
[Google Scholar]
[3]Amsyar F, Siang TC, Sulaiman A, Khun MC. Numerical and experimental study of semi-rigid beam-to-column composite connections in cold-formed steel. In AIP conference proceedings 2020. AIP Publishing LLC.
[Crossref] [Google Scholar]
[4]Sulaiman A, Salleh NM, Sukardi N, Siang TC, Saggaff A. Experimental evaluation of composite beam-to-column joint using cold-formed steel sections. In IOP conference series: materials science and engineering 2019 (pp.1-13). IOP Publishing.
[Crossref] [Google Scholar]
[5]Firdaus M, Saggaff A, Tahir MM, Aghlara R, Sulaiman A, Aminuddin K, et al. Influence of seat angles on the behaviour of cold-formed steel concrete composite joints. Journal of Constructional Steel Research. 2020.
[Crossref] [Google Scholar]
[6]Aminuddin K, Saggaff A, Tahir MM, Ngian SP, Sulaiman A, Firdaus M, et al. Analytical and experimental investigation on slip-in gusset plate connection for double c-channel sections of cold-formed steel. The Open Civil Engineering Journal. 2019; 13:210-7.
[Crossref] [Google Scholar]
[7]Aminuddin KM, Saggaff A, Tahir MM, Ngian SP, Sulaiman A, Firdaus M, et al. Behaviour of rectangular gusset plate with angle cleat connections for cold-formed steel section. In IOP conference series: materials science and engineering 2020 (pp. 1-8). IOP Publishing.
[Crossref] [Google Scholar]
[8]Firdaus M, Saggaff A, Tahir MM, Aminuddin KM, Ngian SP, Siang TC, et al. Behavior of partial strength of beam-to-column connection with gusset plate for cold-formed steel sections. ASEAN Engineering Journal. 2020; 10(2):99-114.
[Google Scholar]
[9]Hanisha CS, Kishore IS. Experimental and finite element analysis of cold formed steel beam-column joint. Materials Today: Proceedings. 2020; 33(1):480-3.
[Crossref] [Google Scholar]
[10]Muliawan S, Saggaff A, Mahmood T, Firdaus M, Aminuddin KM. Loading capacity calculation of integrated precast slab and column panel using cold-formed steel. In journal of physics: conference series 2021 (pp. 1-7). IOP Publishing.
[Crossref] [Google Scholar]
[11]Armo AA, Saggaff A, Tahir MM, Ngian SP, Sulaiman A, Salih MN. Behaviour of rebar shear connector in a push test for composite beam with cold-formed steel section. In IOP conference series: materials science and engineering 2019 (pp.1-10). IOP Publishing.
[Crossref] [Google Scholar]
[12]Salih MN, Tahir MM, Mohammad S, Ahmad Y, Sulaiman A, Shek PN, et al. Experimental study on flexural behaviour of partially encased cold-formed steel composite beams using rebar as shear connector. In IOP conference series: materials science and engineering 2019 (pp. 1-8). IOP Publishing.
[Crossref] [Google Scholar]
[13]Khadavi MM, Salih MN, SA AA, Shek PN. Behaviour of composite beam arranged as boxed-section with c-channel of cold-formed steel of lipped section. In IOP conference series: materials science and engineering. 2020 (pp.1-9).
[Crossref] [Google Scholar]
[14]Lawan MM, Shek PN, Tahir MM. Flexural performance of cold-formed steel section in a composite beam system. In IOP conference series: materials science and engineering 2020 (pp. 1-12). IOP Publishing.
[Crossref] [Google Scholar]
[15]Salih MN, Tahir MM, Mohammad S, Ahmad Y, Shek PN, Abraham A, et al. Bending experiment on a novel configuration of composite system using rebar as shear connectors with partially encased cold-formed steel built-up beams. Materials Today: Proceedings. 2021; 39(2):999-1005.
[Crossref] [Google Scholar]
[16]Firdaus M, Saggaff A, Tahir M, Ngian SP, Sulaiman A, Salih MN. Experimental and analytical study on composite connection with cold-formed steel of double channel sections. In IOP conference series: materials science and engineering 2019 (pp. 1-10). IOP Publishing.
[Crossref] [Google Scholar]
[17]Firdaus M, Saggaff A, Tahir MM, Ngian SP, Sulaiman A. Prediction of moment resistance of steel connection with macro excel using eurocode standard. In journal of physics: conference series 2019 (pp. 1-10). IOP Publishing.
[Crossref] [Google Scholar]
[18]Lawan MM, Shek PN, Tahir MM. Can cold-formed steel section be use as a sustainable structural member in building and Civil engineering constructions? a mini review. In IOP conference series: materials science and engineering 2020 (pp. 1-13). IOP Publishing.
[Crossref] [Google Scholar]
[19]Qiao W, Yan X, Zhu R, Wang F, Wang D. Flexural properties of new cold-formed thin-walled steel and concrete composite slabs. Journal of Building Engineering. 2020.
[Crossref] [Google Scholar]
[20]Standard B. Eurocode 3—design of steel structures—. BS EN 1993-1-8:2005.
[Google Scholar]
[21]https://shop.bsigroup.com/ProductDetail?pid=000000000030283899. Accessed 26 October 2020.